WCDMA2100 40W Digital Fiber Optical Repeater



Frequency: Uplink 1920-1960MHz
Downlink 2110-2150MHz
Max.Gain: 55dB
Max.Output Power: 48dBm
>>Introduction
    WCDMA2100MHz 3G FIber Optical Repeater is the equipment for the network optimization in the mobile network that can enlarge the BTS coverage. It is widely used in the shaded area, high traffic load area and the pilot pollution area, etc.
 
>>Working Principle
The Downlink,master unit of TX/RX receives the downlink(DL)signal from BTS through the couple,is amplified by DL Amplifier and Input Power Detection.
    The RF signal converts to IF signal by using a mixer. IF signal transform into digital signal by digital module, which has included technologies of D/A conversion、digital down-conversion and digital filtering.  The digital optical signal is transmitted via master optic unit and fiber to the remote unit,in which digital optic signal is converted back to (Digital filtering 、digital Up-conversion and A/D conversion)RF signal via remote unit . RF signal is amplified in the DL AMP(Amplifier) and PA(Power Amplifier) to meet a required output power level,and then to remote DL filter, and transmit at port of “To Service (TX) port.”
    The uplink RF signal of mobile terminal in the coverage area is inputted by the port of the “To Service (TX)”, which is filtered by duplexer and amplified by the ULNA (Uplink Low Noise Amplifier).
Same as DL, using mixer to convert UL RF signal to IF signal, which convert to digital optical signal by using technologies of D/A conversion、digital down-conversion and digital filtering. The digital optical signal have been transmitted via master optic unit and fiber to remote unit, in which optic signal converted back to RF(Digital filtering 、digital Up-conversion and A/D conversion)signal then being amplified 、flittered by the UL AMP(Amplifier)and duplexer, after all processing, the signal are going to be transmitted at port of“ RX Port.”
    The main controlling panel (PCM) of master unit and remote unit will control their modules and communicate with each other via the data link of the optic modules. User can inquire and set the parameters by LOC (local monitoring) interface on the master/remote unit. and user also can do in the OMC(Operation and Maintenance Center) by IP network.
    Power supply unit, which supplies power to all the active modules and in charge of charging battery.

>>Applications

parameter
Downlink 
Uplink 
Frequency Range
2110-2150MHz
1920-1960MHz
Output Power (Max.)
     48±2dBm(60W)
-10±2dBm
 Gain (Max.)
55±3dB
 50±3dB
Working band
40MHz
MAX. Carrier
≤6CH(Optional in40MHz)
Group delay
Repeater delay:≤10μs(One with one,Fiber optical pigtail 1m)
System delay:≤25μs(One with six,Fiber optical pigtail 1m);
Delay compensation range:≥ 100μs  automatic or manually compensation
Delay calibration step:≤1μs;
Out-of-Band Rejection
offset ≥2.7MHz
≥65dBc
offset ≥3.5MHz
≥65dBc
offset ≥7.5MHz
≥65dBc
offset≥12.5MHz
≥65dBc
Spurious emission
9kHz~150kHz/1kHz, ≤-36dBm
150kHz~30MHz/10kHz, ≤-36dBm
30MHz~1GHz/100kHz, ≤-36dBm
1GHz~Fc1 - 60 MHz or 2100 MHz whichever is the higher, ≤-30dBm/1MHz
1GHz~Fc1 - 60 MHz or 1910 MHz, whichever is the higher ≤-30dBm/1MHz
Fc1 - 60 MHz or 2100 MH whichever is the higher ~ Fc1 - 50 MHz or 2100 MH whichever is the higher≤-25dBm/1MHz
Fc1 - 60 MHz or 1910 MHz whichever is the higher~ Fc1 - 50 MHz or 1910 MHz whichever is the higher ≤-25dBm/1MHz
Fc1 - 50 MHz or 2100 MHz whichever is the higher~ Fc2 + 50 MHz or 2180 MHz whichever is the lower  ≤-15dBm/1MHz
Fc1 - 50 MHz or 1910 MHz  whichever is the higher~ Fc2 + 50 MHz or 1990 MHz whichever is the lower≤-15dBm/1MHz
Fc2 + 50 MHz or 2180 MHz whichever is the lower~Fc2 + 60 MHz or 2180 MHz whichever is the lower  ≤-25dBm/1MHz
Fc2 + 50 MHz or 1990 MHz whichever is the lower ~ Fc2 + 60 MHz or 1990 MHz whichever is the lower ≤-25dBm/1MHz
Fc2 + 60 MHz or 2180 MHz whichever is the lower ~ 12.75 GHz ≤-30dBm/1MHz
Fc2 + 60 MHz or 1990 MHz whichever is the lower ~ 12.75 GHz ≤-30dBm/1MHz
Spurious emission(special)
806-835MHz,880-915MHz,1710-1785MHz,1785-1805MHz,≤-98dBm/100kHz
854-880MHz,930-960MHz,≤-57dBm/100kHz
1805-1880MHz,≤-47dBm/100kHz
1880-1910MHz,≤-86dBm/100kHz
2100(1910)-2120(1930) MHz,≤-52(-86)dBm/1MHz
2120(1930)-2125(1935) MHz,≤-30dBm/1MHz
2125(1935)-2130(1940) MHz,≤-15dBm/1MHz
2145(1955)-2150(1960) MHz,≤-15dBm/1MHz
2150(1960)-2155(1965) MHz,≤-30dBm/1MHz
2155(1965)-2175(1985) MHz,≤-52(-86)dBm/1MHz
2300-3600MHz,≤-86dBm/1MHz
Mechanical Specifications:
Power Supply
Master unit:DC -48V±9.6V or AC: 90~270V
Remote unit:AC 110V/220V,45~60Hz
Dimension and Weight
Master Unit: 482 mm* 350 mm*130mm, ≤12kg
Remote Unit: 1199mm*265mm*416mm, ≤50kg
Max. Power Consumption
Master Unit: ≤90W
Remote Unit: ≤650W
Operating Temperature
Master Unit: 0~+45℃
Remote Unit: -25~+55℃
Operating Humidity
Master Unit: ≤85%
Remote Unit:  ≤95%
Environmental Class
Master Unit: IP30
Remote Unit:  IP65
RF Connector
N-Female, 50ohm
MTBF
≥50000 hours
Monitor Interface
Local Monitor: TCP/IP or RS232, Remote Monitor: TCP/IP or  Modem SMS